, Paneratech

We have been reflecting on the last two years since SmartMelter® became available to the glass industry two years ago. Over that time, we inspected over 100 furnaces in 27 countries. What we found in the process is that many of the industry’s assumptions about furnace health are not accurate.

Because high risk furnaces have been the initial target of SmartMelter®, we found an unusually high 22% of the furnaces that we inspected had glass penetration into insulation. We also found that the industry is being quite a bit conservative in some areas. SmartMelter® enabled a majority of our customers to delay both overcoat timing and rebuilds because the industry plans such repairs conservatively, primarily based on glass pull.
During this time, we also debunked two popular myths:

Myth 1: Glass penetration into insulation may lead to a major leak within hours or days.
Glass penetration into insulation can actually last over a year or two before turning into a major leak. We’ve had customers start with about 200 mm total insulation thickness left in the bottom and run the furnace for another 2 years with smart cooling and regular SmartMelter® monitoring.

Myth 2: A surface temperature of 500C is the most commonly used guidance for overcoat planning.
Actually, 500C does not necessarily indicate the furnace needs an overcoat in container and flat glass furnaces. On furnaces with poor cooling methods, 500C resulted in a thickness range of 60-100mm. Even on furnaces that have had very good cooling, 500C indicated a thickness range of 30-50mm. The majority of our customers are targeting 20-25mm when planning for overcoat, so this data effectively increases the campaign life of the furnace.


Our data is laying the foundation for smarter maintenance decisions. We are confident that we will contribute more valuable information as our work continues. I look forward to bringing you more new insights as we discover them.

, © Paneratech

Il materiale informativo del sito è registrato ed appartiene all´azienda o ai terzi che lo hanno fornitoe tutti i diritti sono riservati. Qualsiasi utente che accede a tale materiale può farlo solo ad uso personale e ne è anche responsabile. Ridistribuzione o altro uso commerciale di tale materiale è espressamente proibito. Nel caso in cui il materiale sia stato ceduto da terzi, l´utente concorda di rispettare questi termini di utilizzo specificati. Glass Global non garantisce la veridicità o l´esattezza del contenuto di alcuna informazione o di siti web esterni menzionati nelle stesse.

Should the content or the design of these sites violate third parties rights or legal prescriptions, we kindly ask you to send us a respective message without invoice or cost. We guarantee that passages where the claim is considered as justified will be removed immediately, without any necessity to involve any lawyer into this issue. We will reject any claim caused by submission of a honorary note in this regard without any prior contact and confirmation of the issueby us and we reserve the right ssue counter claim ourselves because of violation of aforesaid conditions.



Info Grid

Glass studies

Updated worldwide glass study 2024

plants.glassglobal.com

Updated hollow glass study 2024

Request more information

Updated float glass study 2024

Request more information

Further glass market studies

Request more information

Profilo Aziendale



Updated worldwide glass market study 2024 available now for flat, container glass and tableware

We have updated our international studies on flat glass, container glass and tableware for 2024.

This unique software provides a global overview about glass producers and technical details. Easy to use and clear tables summarize information and data about glass makers such as: Glass types: flat glass, container glass, tableware, production capacities in regions and countries, number of furnaces, furnace types, year of construction, glass types and sub-types, products, project information, special news and downloads.

Further databases supplying demoscopic data and import and export data complete the market survey. Based on these data, prepare individual country profiles with information about local production capacities, local market sizes and expected demand in the future.

Request your offer via plants.glassglobal.com.

Updated container glass study 2024

X

Updated float glass study 2024

X

Further glass studies and reports 2024

X