ON-SITE COMMISSIONINGS – INSULATING GLASS GAS ANALYSIS WITH SPARKLIKE LASER™

, Sparklike Oy

Lasifakta Oy and Sparklike Oy were asked to go on-site and control the level of implementation for, among other things, the insulating glass gas fill content. The chosen locations where 1) a well-known building in one of the European capitals and 2) an international airport in Europe. The quality control of IG gas fill levels was conducted by using Sparklike Laser Portable™ device that enables non-destructive insulating gas analysis for triple and double glazed IGU’s, even through coatings and laminated glasses. Sparklike Laser Portable™ has the whole system integrated into a robust case, allowing easy mobility in factories and on building sites.

“I have been pleased to find out that growing number of our collaborators are keen on contacting us in the very beginner stages of the construction planning process, “ Mr. Tahvo Sutela from Lasifakta says. 

One of the European capitals commissioned Lasifakta to conduct an on-site quality control measurement to one of the buildings they own. Their main goal was to construct a high-quality building, and therefore they wanted to make sure that the implementation had happened according to the original plan. During the visit, Lasifakta and Sparklike randomly selected and measured 8 already installed triple glazed IGU’s.

The same units were measured multiple times. Both, the commissioner as well as the contractor were particularly pleased about the additional information they received concerning the insulating glass gas fill concentration levels of already installed IGU’s.  

The other commissioning case for an on-site quality control took place at an international European airport where Lasifakta and Sparklike went to check insulating glass gas concentration, and therefore building’s energy efficiency. Also with this case, it was important to check that the level of implementation had happened according to the original plan. Furthermore, also in this commissioning, the measured units were selected randomly. The measurement sample included both, double and triple glazed IGU’s. When analysing customized double glazed IGU’s, the gas fill levels did not always fulfil the industry requirements, since the average gas fill concentration varied between 1% and 82%. The on-site insulating gas concentration analysis act as a prime example, where the contractor has the possibility to verify that the level of implementation had happened according to the original plan. In terms of DGU and TGU it meant that the measured units fulfilled the prevailing energy efficiency requirements. 
 

“These two commissioning cases are a clear indication of the need as well as the growing interest towards on-site IG gas fill percentage measurement. The contractors were happy to notice that it is now possible to analyse IGU’s gas concentration reliably, repeatable and most importantly – also on-site. All in all, I hope that with the help of these on-site measurements we will soon be able to witness a significant improvement in production quality control,” Mr. Sutela concludes.

To sum up, Lasifakta firmly believes that customer expectations fulfilling, cost-effective and sensible glass planning as well as consulting can be achieved by identifying and considering the limitations and opportunities of different glass products and production technologies. This, on the other hand, allows significant cost saving, cost management and the possibility to confront any time management challenges head on.
 

, © Sparklike Oy

Il materiale informativo del sito è registrato ed appartiene all´azienda o ai terzi che lo hanno fornitoe tutti i diritti sono riservati. Qualsiasi utente che accede a tale materiale può farlo solo ad uso personale e ne è anche responsabile. Ridistribuzione o altro uso commerciale di tale materiale è espressamente proibito. Nel caso in cui il materiale sia stato ceduto da terzi, l´utente concorda di rispettare questi termini di utilizzo specificati. Glass Global non garantisce la veridicità o l´esattezza del contenuto di alcuna informazione o di siti web esterni menzionati nelle stesse.

Should the content or the design of these sites violate third parties rights or legal prescriptions, we kindly ask you to send us a respective message without invoice or cost. We guarantee that passages where the claim is considered as justified will be removed immediately, without any necessity to involve any lawyer into this issue. We will reject any claim caused by submission of a honorary note in this regard without any prior contact and confirmation of the issueby us and we reserve the right ssue counter claim ourselves because of violation of aforesaid conditions.



Info Grid

Glass studies

Updated worldwide glass study 2024

plants.glassglobal.com

Updated hollow glass study 2024

Request more information

Updated float glass study 2024

Request more information

Further glass market studies

Request more information

Profilo Aziendale



Updated worldwide glass market study 2024 available now for flat, container glass and tableware

We have updated our international studies on flat glass, container glass and tableware for 2024.

This unique software provides a global overview about glass producers and technical details. Easy to use and clear tables summarize information and data about glass makers such as: Glass types: flat glass, container glass, tableware, production capacities in regions and countries, number of furnaces, furnace types, year of construction, glass types and sub-types, products, project information, special news and downloads.

Further databases supplying demoscopic data and import and export data complete the market survey. Based on these data, prepare individual country profiles with information about local production capacities, local market sizes and expected demand in the future.

Request your offer via plants.glassglobal.com.

Updated container glass study 2024

X

Updated float glass study 2024

X

Further glass studies and reports 2024

X